Model TWBS.EWE, lead-free Emergency Valve (patent pending) thermostatically mixes hot and cold water to provide a safe fluid supply for emergency eyewash equipment. The valve contains a secondary high temperature limit valve to provide additional protection to the user in the event of main tempering valve malfunction. Additionally, to ensure a fail-safe water supply for emergency shower and eyewash stations, a series of cold water by-pass valves open in the event of hot water pressure loss. (No gauges supplied – ASSE 1071 standard recommends gauges be placed 5 to 8 feet (1.52 to 2.44 m) downstream for the most accurate temperature measurement.)
- A flow rate of 1 to 12 gpm (3.8 to 45.4 L) for better temperature control across the operating range
- AXION’s superior design and technology provide a complete safety solution for increased victim comfort.
- Lowest internal pressure drop for this class of valve (advantage where supply pressure is low)
- Wax based thermostat technology for fast response time with proven highly reliable temperature control
- Highest Cold Water Bypass flow rate in the industry (83% of rated tepid flow rate)
- Modular lead-free brass design with internal check stops
- Over-sized valve seats resist failures caused by foreign matter
- A new and efficient shuttle design eliminates valve binding
- A custom funnel design improves temperature control at low flow rates
- Outlet temperature is factory set to 85® F (29® C)
- Tempered water: High temperature limit is factory set to 87® F (30® C)
- Cold water by-pass valves are closed during normal operation, regardless of flow rate
Listings: ASSE 1071, CSA B125.3, NSF/ANSI 372, NSF/ANSI 61-section 8, California Health and Safety Code 116875 (AB 1953).
TWBS.HF – Thermostatic Mixing ValveModel TWBS.HF, lead-free Emergency Valve (patent pending), thermostatically mixes hot and cold water to provide a safe fluid supply for emergency shower and eyewash equipment. The valve contains a secondary high temperature limit valve to provide additional protection to the user in the event of main tempering valve malfunction. Additionally, to ensure a fail-safe water supply for emergency shower and eyewash stations, a pressure sensing diverter valve is provided that sends a pressure signal to open the cold water by-pass valve in the event of hot water pressure loss, main valve thermostat malfunction, or clogged cold water check-stop. (No gauges supplied – ASSE 1071 standard recommends gauges be placed 5 to 8 feet (1.52 to 2.44 m) downstream for the most accurate temperature measurement.)
- A flow rate of 1 to 78 gpm (295 L) for better temperature control across the operating range
- AXION’s superior design and technology provide a complete safety solution for increased victim comfort.
- Lowest internal pressure drop for this class of valve (advantage where supply pressure is low)
- Wax based thermostat technology for fast response time with proven highly reliable temperature control
- Highest Cold Water Bypass flow rate in the industry (100% of rated tepid flow rate)
- Modular lead-free brass design with internal check stops
- Over-sized valve seats resist failures caused by foreign matter
- A new and efficient shuttle design eliminates valve sticking
- A custom funnel design improves temperature control at low flow rates
- Outlet temperature is factory set to 85® F (29® C)
- Tempered water: High temperature limit is factory set to 87® F (30® C)
- Cold water by-pass valves are closed during normal operation, regardless of flow rate
Listings: ASSE 1071, CSA B125.3, NSF/ANSI 372, NSF/ANSI 61-section 8, California Health and Safety Code 116875 (AB 1953).
TWBS.SHE – Thermostatic Mixing ValveModel TWBS.SHE, lead-free Emergency Valve (patent pending), thermostatically mixes hot and cold water to provide a safe fluid supply for emergency shower and eyewash equipment. The valve contains a secondary high temperature limit valve to provide additional protection to the user in the event of main tempering valve malfunction. Additionally, to ensure a fail-safe water supply for emergency shower and eyewash stations, a series of cold water by-pass valves open in the event of hot water pressure loss. (No gauges supplied – ASSE 1071 standard recommends gauges be placed 5 to 8 feet (1.52 to 2.44 m) downstream for the most accurate temperature measurement.)
- A flow rate of 1 to 74 gpm (280 L) for better temperature control across the operating range
- AXION’s superior design and technology provide a complete safety solution for increased victim comfort.
- Lowest internal pressure drop for this class of valve (advantage where supply pressure is low)
- Wax based thermostat technology for fast response time with proven highly reliable temperature control
- Highest Cold Water Bypass flow rate in the industry (68% of rated tepid flow rate)
- Modular lead-free brass design with internal check stops
- Over-sized valve seats resist failures caused by foreign matter
- A new and efficient shuttle design eliminates valve binding
- A custom funnel design improves temperature control at low flow rates
- Outlet temperature is factory set to 85® F (29® C)
- Tempered water: High temperature limit is factory set to 87® F (30® C)
- Cold water by-pass valves are closed during normal operation, regardless of flow rate
Listings: ASSE 1071, CSA B125.3, NSF/ANSI 372, NSF/ANSI 61-section 8, California Health and Safety Code 116875 (AB 1953).
9201E – Thermostatic Mixing Valve – 117 liters/minThe Haws® thermostatic mixing valve model 9201E mixes hot and cold water and provides a safe tepid water supply for emergency showers and eyewash stations. Flow range of 4 to 117 liters/minute provides service for one emergency combination shower or multiple eyewashes, reducing complexity and hardware costs.
Technical information thermostatic mixing valve model 9201E
- Outlet temperature factory setting: 26°C.
- Maximum operating pressure: 8.62 bar.
- Temperature adjustment range: 16 – 35° C.
- Maximum inlet temperature: 82° C.
- Recommended inlet temperature: 60° C.
- Minimum inlet temperature: 49° C
- Water inlets: BSP 1-1/4″
- Water outlet: BSP 1-1/4″
Characteristics
- Best-in-class cold water bypass flow (65% of rated tempered water flow) means continued protection under adverse conditions.
- Actively suspends hot water flow when cold water supply is lost to protect against scalding.
- Lowest internal pressure drop for this valve class – essential where supply pressure is low.
- Paraffin-based thermal actuation technology keeps outlet temperature within tight specifications to prevent scalding and hypothermia.
- Superior shuttle design combined with premium material selection eliminates valve binding and reduces maintenance costs.
- Innovative funnel design generates turbulent flow to ensure consistent temperature blending across entire flow range.
- Lime and calcium resistant materials used throughout prevent valve sticking and provide a long service life.
Model 9201EFE Emergency Valve (patent pending) thermostatically mixes hot and cold water to provide a safe fluid supply for emergency eyewash equipment. Additionally, to ensure a fail-safe water supply for emergency eyewash stations, a series of cold water by-pass valves open in the event of hot water pressure loss. (No gauges supplied – ASSE 1071 standard recommends gauges be placed 5 to 8 feet (1.52 to 2.44 m) downstream for the most accurate temperature measurement.)
- A flow rate of 1 to 12 gpm (3.8 to 45.4 L) for better temperature control across the operating range
- AXION’s superior design and technology provide a complete safety solution for increased victim comfort.
- Lowest internal pressure drop for this class of valve (advantage where supply pressure is low)
- Wax based thermostat technology for fast response time with proven highly reliable temperature control
- Highest Cold Water Bypass flow rate in the industry (83% of rated tepid flow rate)
- Modular brass design with internal check stops
- Over-sized valve seats resist failures caused by foreign matter
- A new and efficient shuttle design eliminates valve sticking
- A custom funnel design improves temperature control at low flow rates
- Outlet temperature is factory set to 85® F (29® C).
- Tempered water: High temperature limit is factory set to 90® F (32® C).
- Cold water by-pass valves are closed during normal operation, regardless of flow rate.
CSA Certifies this product to perform according to the ASSE 1071 standard and applicable sections of CSA B125.3.
9201EW – Thermostatic Mixing ValveModel 9201EW Emergency Valve thermostatically mixes hot and cold water to provide a safe fluid supply for a single emergency eye/face wash. Additionally, to ensure a fail-safe water supply for emergency eyewash stations, a cold water by-pass valves open in the event of hot water pressure loss. (No gauges supplied – ASSE 1071 standard recommends gauges be placed 5 to 8 feet (1.52 to 2.44 m) downstream for the most accurate temperature measurement.)
- A flow rate of 1 to 10 gpm (3.8 to 37.8 L) for better temperature control across the operating range
- AXION’s superior design and technology provide a complete safety solution for increased victim comfort.
- Wax based thermostat technology for fast response time with proven highly reliable temperature control
- Cold Water Bypass flow rate of 3.8 gpm (14.4 L) (When tested under conditions specified in ASSE 1071)
- Modular brass design with supplied check valves
- Over-sized valve seats resist failures caused by foreign matter
- Efficient funnel design improves temperature control at low flow rates
- Outlet temperature is factory set to 85® F (29® C).
- Tempered water: High temperature limit is factory set to 90® F (32® C).
CSA Certifies this product to perform according to the ASSE 1071 standard and applicable sections of CSA B125.3.
9202E – Thermostatic Mixing ValveModel 9202E Emergency Valve (patent pending) thermostatically mixes hot and cold water to provide a safe fluid supply for emergency showers and eyewash equipment. Additionally, to ensure a fail-safe water supply for emergency shower and eyewash stations, a series of cold water by-pass valves open in the event of hot water pressure loss. (No gauges supplied – ASSE 1071 standard recommends gauges be placed 5 to 8 feet (1.52 to 2.44 m) downstream for the most accurate measurement.)
- A flow rate of 1 to 78 gpm (295 L) for better temperature control across the operating range
- Lowest internal pressure drop for this class of valve (advantage where supply pressure is low)
- Wax based thermostat technology for fast response time with proven highly reliable temperature control
- Highest Cold Water Bypass flow rate in the industry (64% of rated tepid flow rate)
- Modular brass design with internal check stops
- Over-sized valve seats resist failures caused by foreign matter
- A new and efficient shuttle design eliminates valve sticking
- A custom funnel design improves temperature control at low flow rates
- Outlet temperature is factory set to 85® F (29® C).
- Tempered water: High temperature limit is factory set to 90® F (32® C).
- Cold water by-pass valves are closed during normal operation, regardless of flow rate.
CSA Certified to ASSE 1071 and applicable sections of CSA B125.3.